How to Write an RTLS RFP for Elopement and Staff Duress: Performance-Based Specifications That Get Honest Bids
By the MGM Solutions team – life-safety RTLS specialists since 2002.
Many requests for proposal for patient elopement or staff duress systems are written by copying the
brochure of the system the facility already knows. The specification ends up listing one vendor’s
features, sometimes down to model numbers, and every other bidder either bids a near copy or does not
bid at all. The facility gets fewer choices, less price competition, and a contract that describes a
product instead of the protection it actually needed.
There is a better way. A performance-based RTLS RFP states what the system must accomplish, how
quickly, and where, and then tells bidders how those claims will be tested before the system is
accepted. This guide walks through how to write one for life-safety uses.
Start With the Outcome, Not the Product
Before writing a single requirement, the project team should agree on the outcomes in plain
language. For elopement, that might be: staff are alerted within seconds when an at-risk patient
leaves a defined area, and responders can see where the patient is going, including outside the
building. For duress: any staff member can silently call for help from anywhere they work, and
responders see the exact room.
Those outcome statements become the backbone of the specification. Every requirement that follows
should trace back to one of them. If a requirement cannot be traced to an outcome, ask why it is
there. Often the answer is that it was copied from a brochure.
Federal buyers will recognize this approach. The Federal Acquisition Regulation directs agencies to
state requirements in terms of functions and performance where practical, and brand-name-only
requirements need a written justification. Private and state buyers are not bound by the FAR, but the
logic is the same: performance language gets more qualified bids.
Specify Coverage Where Risk Actually Is
Coverage is where life-safety RFPs most often go wrong. A requirement to “monitor exit doors” will
be met by a door-only system that sees nothing between the doors and nothing outside them. If your
risk includes stairwells, courtyards, parking areas, or patients removing their tags, the RFP has to
say so.
Write coverage as a map, not a sentence. Attach floor plans and site plans, mark the areas that
require room-level location, the areas that require boundary detection, and the outdoor areas that
must be covered. Our article on
full-floor RTLS versus
door-only monitoring explains why this distinction drives both safety and price.
Turn Every Claim Into a Testable Requirement
Words like “real-time,” “accurate,” and “reliable” mean nothing in a contract unless they come with
a number and a test. The table below shows the difference.
| Weak Specification | Performance-Based Requirement | How to Verify at Acceptance |
|---|---|---|
| “System shall use [brand] tags and receivers” | Wearable tag that identifies the wearer and reports location continuously throughout the covered areas | Walk test with tags on staff along a defined route |
| “Real-time alerts” | Alert delivered to assigned staff within a stated number of seconds of a boundary crossing | Timed crossings at every monitored exit, logged by the system |
| “Accurate location” | Room-level location in designated clinical areas; stated accuracy in open areas | Room-by-room placement test against the floor plan |
| “Monitors exits” | Continuous tracking indoors and in designated outdoor areas, per attached site plan | Outdoor walk test through courtyards and parking areas |
| “Long battery life” | Low-battery and tag-removal alerts sent automatically, before the tag stops reporting | Remove a tag and use a low-battery test tag during acceptance |
| “Panic button capability” | Silent duress from a wearable badge, showing wearer identity and room to responders | Press tests in every covered zone, including stairwells and outdoors |
Two requirements deserve special attention. First, supervision: the system should tell staff when a
tag stops reporting, is removed, or is running low, rather than failing silently. We explain why in
Understanding
RTLS Tag Battery and Tamper Supervision. Second, alert latency, measured end to end from the event
to the alert in a responder’s hand, as covered in our
article on alert
latency.
Ask About the Network Underneath
Many RTLS proposals depend on the hospital’s Wi-Fi or a Bluetooth beacon network. That can work for
asset tracking, but life-safety alerts carried over a shared network compete with everything else on
it. The RFP should ask each bidder to state what network the system depends on, what happens to alerts
when that network is congested or down, and who is responsible for maintaining it. Our pillar page on
why Wi-Fi, BLE, and 900 MHz fall short
for life-safety RTLS explains the questions to ask.
Questions That Belong in Every Life-Safety RTLS RFP
- What areas, indoors and outdoors, does the proposed system cover, and at what location
resolution in each? - What is the end-to-end alert time from a boundary crossing or duress press to a staff
device? - How does the system detect and report a removed tag, a dead battery, or a failed receiver?
- What network does the system depend on, and what happens to alerts if that network fails?
- Can elopement, staff duress, infant security, and asset tracking run on the same infrastructure,
or does each require separate hardware? - How does the system integrate with access control, elevators, cameras, and nurse call?
- Provide references at comparable facilities, with contacts who can describe performance after
several years in service.
We use a similar checklist with our own prospects, and our
comparison of campus-wide RTLS
approaches shows how different system types answer these questions. Ask every bidder, including
us, to answer in writing.
Make Acceptance Testing Part of the Contract
The single most effective protection in an RTLS contract is a written acceptance test that mirrors
the requirements: walk tests, timed alerts, tag removal, outdoor coverage, and duress presses in every
zone, performed before final payment. When bidders know their claims will be measured, the proposals
get more honest. For the financial side of the decision, see
How to Build a
Business Case for Hospital RTLS.
Frequently Asked Questions
What should an RTLS RFP include?
An RTLS RFP should include plain-language outcomes, coverage maps showing where room-level, boundary, and outdoor tracking are required, measurable performance requirements such as alert time, tag supervision requirements, network dependency questions, integration needs, references, and a written acceptance test.
Why avoid brand-name specifications in an RTLS RFP?
Brand-name specifications limit competition, raise prices, and describe a product instead of the protection the facility needs. Performance-based requirements let any qualified vendor bid and make it easier to hold the winner to measurable results. Federal agencies also need a written justification for brand-name-only requirements.
How do you verify RTLS performance before accepting a system?
Run an acceptance test that mirrors the specification: walk tests along defined routes, timed boundary crossings at every monitored exit, room-by-room placement checks, tag removal and low-battery tests, outdoor coverage tests, and duress presses in every covered zone.
Should elopement and staff duress be in the same RFP?
Often, yes. If one infrastructure can support elopement prevention, staff duress, infant security, and asset tracking, buying them together avoids duplicate hardware and separate networks. Ask bidders to state clearly which uses share infrastructure and which need separate equipment.
What is the most common mistake in life-safety RTLS RFPs?
Writing coverage as a single sentence such as monitor exit doors. That language is satisfied by door-only systems that see nothing between doors or outside the building. Attach floor plans and site plans that mark exactly where each level of tracking is required.
Talk to an RTLS Expert
M.G.M. Computer System, Inc. (dba MGM Solutions) has delivered life-safety RTLS to VA medical
centers, hospitals, and corrections facilities since 2002, with 99.8% uptime and 40+ VA
projects as prime contractor. We are a CVE-verified Service-Disabled Veteran-Owned Small Business.
Tell us what you are trying to protect and we will tell you, honestly, whether SecurTRAK is the
right fit, and what it would take to cover your whole campus, indoors and outdoors.
Email:
sales@mgm-solutions.com •
Phone: (856) 371-3764 •
Request a consultation
Related reading:
5 Questions Every
Hospital CIO Should Ask Before Buying RTLS •
RTLS Solutions for Hospital CIOs
•
Campus-Wide
Elopement Prevention